Use este identificador para citar ou linkar para este item:
http://bdtd.uftm.edu.br/handle/123456789/1829
Tipo: | Tese |
Título: | Desenvolvimento de biossensores eletroquímicos para detecção precoce e tratamento oportuno leishmaniose visceral humana em pacientes assintomáticos: novas fronteiras no combate à enfermidade |
Título(s) alternativo(s): | A comparative study of graphene-based electrodes for electrochemical detection of visceral leishmaniasis in symptomatic and asymptomatic patients |
Autor(es): | MARTINS, Beatriz Rodrigues |
Primeiro Orientador: | ALVES, Renata Pereira |
Resumo: | Este trabalho, descreve a importância dos biossensores eletroquímicos para o diagnóstico de doenças. O tema central da tese de doutorado apresentada, baseia-se na descrição de uma metodologia diagnóstica que se refere ao desenvolvimento de um biossensor eletroquímico para a detecção de pacientes sintomáticos e assintomáticos de leishmaniose (LSH), que suprime a reação cruzada com a doença de Chagas (DC). Trata-se de uma doença parasitária transmitida por mosquitos infectados. Seus sintomas, muitas vezes confundidos com outras enfermidades, dificultam o diagnóstico preciso e atrasam o início do tratamento adequado. Desta forma, o desenvolvimento de um biossensor eletroquímico que detecte adequadamente até mesmo os pacientes assintomáticos, e mantenha as características prevalentes nessa técnica, como excelente custo benefício, rápida execução e livre de interferências, faz-se necessário. Assim, eletrodos screen-printed de grafite modificados com óxido de grafeno e foram selecionados como plataformas para a imobilização de antígenos totais brutos de Leishmania infantum. As propriedades eletroquímicas foram avaliadas por voltametria cíclica (0,1 V.s-1). O par redox ferri/ferrocianeto de potássio, possibilitaram a análise dos picos de corrente anódicas e catódicas. As análises comparativas com Enzyme-Linked Immunosorbent Assay (ELISA) indireto foram realizadas com os mesmos grupos de pacientes, em condições semelhantes às desenvolvidas no biossensor eletroquímico. Quanto a curva de calibração, nossos resultados apresentam um limite de detecção (LOD) em 5.58 mg.mL-1. Portanto, este sensor pode ser apresentado como um dispositivo promissor para um diagnóstico eficiente e eficaz dos anticorpos de Leishmaniose, presentes nos soros de pacientes sintomáticos e possivelmente assintomáticos. |
Abstract: | This work describes the importance of electrochemical biosensors for the diagnosis of diseases. The central theme of the doctoral thesis presented is based on the description of a diagnostic methodology that refers to the development of an electrochemical biosensor for the detection of symptomatic and asymptomatic patients with leishmaniasis (LSH), which suppresses the cross-reaction with the disease leishmaniasis. Chagas (DC). It is a parasitic disease transmitted by infected mosquitoes. Its symptoms, often confused with other diseases, make accurate diagnosis difficult and delay the initiation of appropriate treatment. Therefore, it is necessary to develop an electrochemical biosensor that adequately detects even asymptomatic patients, and that maintains the predominant characteristics of this technique, such as excellent cost-benefit, fast execution and free from interference. Therefore, screen-printed graphite electrodes modified with graphene oxide were selected as platforms for the immobilization of raw Leishmania infantum total antigens. The electrochemical properties were evaluated by cyclic voltammetry (0.1 V.s-1). The ferri/potassium ferrocyanide redox couple made it possible to analyze the anodic and cathodic current peaks. Comparative analyzes with Indirect Enzyme Immunosorbent Assay (ELISA) were carried out with the same groups of patients, under conditions similar to those developed in the electrochemical biosensor. As for the calibration curve, our results present a limit of detection (LOD) of 5.58 mg.mL-1. Therefore, this sensor may present itself as a promising device for an efficient and effective diagnosis of antibodies against Leishmaniasis, present in sera from symptomatic and possibly asymptomatic patients. |
Palavras-chave: | Grafeno. Imunossensor. Eletroquímica. Leishmaniose. Assintomáticos. Sintomáticos. Graphene. Immunosensor. Electrochemistry. Leishmaniasis. Asymptomatic. Symptomatic. |
CNPq: | CNPQ::CIENCIAS BIOLOGICAS |
Idioma: | por |
País: | Brasil |
Editor: | Universidade Federal do Triângulo Mineiro |
Sigla da Instituição: | UFTM |
metadata.dc.publisher.department: | Instituto de Ciências Tecnológicas e Exatas - ICTE::Programa de Mestrado Profissional em Inovação Tecnológica |
metadata.dc.publisher.program: | Programa de Mestrado Profissional em Inovação Tecnológica |
Tipo de Acesso: | Acesso Aberto |
URI: | http://bdtd.uftm.edu.br/handle/123456789/1829 |
Data do documento: | 19-Ago-2024 |
Aparece nas coleções: | Programa de Pós-Graduação em Ciências Fisiológicas |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Tese Beatriz R Martins.pdf | Tese Beatriz R Martins | 6,58 MB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.