Biblioteca Digital de Teses e Dissertações PÓS-GRADUAÇÃO SCTRICTO SENSU Pró-Reitoria de Pesquisa e Pós-Graduação Programa de Pós-Graduação em Ciência e Tecnologia Ambiental
Use este identificador para citar ou linkar para este item: http://bdtd.uftm.edu.br/handle/123456789/1946
Registro completo de metadados
Campo DCValorIdioma
dc.creatorABRÃO, Ana Letícia Santos-
dc.creator.Latteshttp://lattes.cnpq.br/1785531517953691pt_BR
dc.contributor.advisor1FERREIRA, Deusmaque Carneiro-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9980479864325695pt_BR
dc.date.accessioned2025-07-11T18:28:50Z-
dc.date.available2023-08-30-
dc.date.available2025-07-11T18:28:50Z-
dc.date.issued2023-08-30-
dc.identifier.urihttp://bdtd.uftm.edu.br/handle/123456789/1946-
dc.description.resumoOs metais potencialmente tóxicos possuem a capacidade de bioacumulação em tecidos dos corpos de organismos vivos e podem causar efeitos toxicológicos nas propriedades do solo e para a saúde humana e de animais. Existem várias metodologias disponíveis para a quantificação de metais em matrizes aquosas. No entanto, essas técnicas se tornam dispendiosas devido ao alto custo e a necessidade de profissionais especializados para manuseio dos equipamentos. Sendo assim, o objetivo deste trabalho foi a aplicação do eletrodo de ouro (EAu) sem modificações em sua superfície a fim de analisar a presença de íons Pb2+ em águas superficiais do Córrego Lanoso em Uberaba – MG, por meio da voltametria de redissolução anódica, sem que haja necessidade de preparo da amostra. Os parâmetros voltamétricos foram otimizados com o auxílio do Delineamento Composto Central Rotacional (DCCR) e a validação do método foi realizada mediante espectrofotômetro de emissão atômica (MP-AES 4200 Agilent). As análises empregando o sensor eletroquímico apontaram limites de detecção (LD) de 0,04 ng L-1 e limite de quantificação (LQ) de 0,13 ng L-1. Ademais, foram constatados teores de chumbo na amostra real evidenciando a efetividade ao empregar o EAu sem modificações, para detectar íons Pb2+ em águas naturais (abastecimento público). Em síntese, tal metodologia demonstrou eficaz na quantificação dos íons Pb2+ em concentração no ambiente, fácil manuseio, análise em tempo real, sem a necessidade de preparo da amostra, restando os estudos de viabilidade econômica para implementação comercial do referido sensor eletroquímico.pt_BR
dc.description.abstractPotentially toxic metals could bioaccumulate in body tissues of living organisms and can cause toxicological effects on soil properties and human and animal health. There are several methodologies available for the quantification of metals in aqueous matrices. However, these techniques become expensive due to the high cost and the need for specialized professionals to handle the equipment. Therefore, the objective of this work was the application of the gold electrode (EAu) without modifications on its surface in order to analyze the presence of Pb2+ ions in surface waters of Córrego Lanoso in Uberaba - MG, through anodic stripping voltammetry, without the need for sample preparation. The voltammetric parameters were optimized with the aid of the Rotational Central Composite Design (DCCR) and the validation of the method was performed using an atomic emission spectrophotometer (MP-AES 4200 Agilent). The analyzes using the electrochemical sensor showed limits of detection (LD) of 0.04 ng L-1 and limit of quantification (LQ) of 0.13 ng L-1. Furthermore, lead levels were found in the real sample, evidencing the effectiveness of using the EAu without modifications, to detect Pb2+ ions in natural waters (public supply). In short, this methodology proved effective in quantifying Pb2+ ions in concentration in the environment, easy handling, real-time analysis, without the need for sample preparation, leaving only economic feasibility studies for the commercial implementation of the aforementioned electrochemical sensor.pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal do Triângulo Mineiropt_BR
dc.publisher.departmentPró-Reitoria de Pesquisa e Pós-Graduaçãopt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.initialsUFTMpt_BR
dc.publisher.programPrograma de Pós-Graduação em Ciência e Tecnologia Ambientalpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectEletroanalítica ambiental.pt_BR
dc.subjectVoltametria de redissolução anódica.pt_BR
dc.subjectEletrodo de ouro.pt_BR
dc.subjectMetais potencialmente tóxicos.pt_BR
dc.subjectQualidade da água.pt_BR
dc.subjectEnvironmental electroanalyticals.pt_BR
dc.subjectAnodic stripping voltammetry.pt_BR
dc.subjectGold electrode.pt_BR
dc.subjectPotentially toxic metals.pt_BR
dc.subjectWater quality.pt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICApt_BR
dc.titleEletrodo de ouro como sensor eletroquímico para monitoramento de chumbo em águas naturais para abastecimento públicopt_BR
dc.typeDissertaçãopt_BR
Aparece nas coleções:Programa de Pós-Graduação em Ciência e Tecnologia Ambiental

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissert Ana L S Abrao.pdfDissert Ana L S Abrao3,55 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.